Call 08048606774 62% Response Rate

Send Email

Load Cell

Our range of products include double ended shear beam load cell, single ended shear beam load cell, button load cell and s-type load cell.
Double Ended Shear Beam Load Cell
  • Double Ended Shear Beam Load Cell
  • Double Ended Shear Beam Load Cell

Double Ended Shear Beam Load Cell

Get Latest Price

Product Brochure

Product Details:
BrandZemic
ModelB9C
TypeDouble Ended Shear Beam
Capacity10 Ton
MaterialStainless Steel
Ingress ProtectionIP67
ApplicationTank & Vessel Weighing
FeaturesHermetically sealed, High Accuracy & Precision
Load Cell CertificationsNTEP, ATEX
Output Sensitivity(FS)3.0 +/- 0.003 mV/V
Combined Error<= +/- 0.035
Creep Error (30 minutes)<= +/- 0.016
Accuracy ClassOIML R60 C3
Temperature Effect on Zero<= +/- 0.016
Temperature Effect on Output<= +/- 0.011
Zero balance+/- 1% FS
Maximum Safe Overload150% FS
Ultimate Safe Overload300% FS
Recommended Excitation Voltage5 to 12V DC
Maximum Excitation Voltage18V DC
Input Resistance700 +/- 7 Ohm
Output Resistance703 +/- 4 Ohm
Insulation resistance at 50V DC>= 5000 M Ohm
Compensated Temperature Range-10 to +40 Deg C
Operating Temperatue Range-30 to +70 Deg C
Load Cell Intervals (nLC)/Divisions3000
Cable Length9 Meter

We deal in good quality Double Ended Shear Beam Load Cell with the most premium standards and performance

Features:

  1. Batching, Blending & Mixing Systems
  2. Excellent Performance for High Capacity Loading
  3. Excellent Combined Error & Repeatability
  4. Level & Inventory Monitoring
  5. Tank, Bin & Silo Weighing
Get Best QuoteRequest A Callback
Single Ended Shear Beam Load Cell
  • Single Ended Shear Beam Load Cell
  • Single Ended Shear Beam Load Cell

Single Ended Shear Beam Load Cell

Get Latest Price

Product Brochure

Product Details:
BrandKeli
ModelSQB
TypeSingle Ended Shear Beam
Capacity3- 10 Ton
MaterialStainless Steel
Ingress ProtectionIP68
ApplicationPallet Truck Scales
Load Cell CertificationsOIML
Output Sensitivity(FS)3.0 +/- 0.003 mV/V
Combined Error<= +/- 0.02
Creep Error (30 minutes)<= +/- 0.02
Accuracy ClassOIML R60 C3
Temperature Effect on Zero<= +/- 0.02
Temperature Effect on Output<= +/- 0.02
Zero balance+/- 1% FS
Maximum Safe Overload150% FS
Ultimate Safe Overload180% FS
Recommended Excitation Voltage10 to 12V DC
Maximum Excitation Voltage15V DC
Input Resistance400 +/- 20 Ohm
Output Resistance350 +/- 3 Ohm
Insulation resistance at 50V DC>= 5000 M Ohm
Compensated Temperature Range-10 to +40 Deg C
Operating Temperatue Range-30 to +70 Deg C
Load Cell Intervals (nLC)/Divisions3000
Cable Length5 Meter

We provide premium quality Single Ended Shear Beam Load Cell with the most superior standards and performance

Application:

  1. Low Profile Floor Scales
  2. Tank, Hopper & Bag Weighing
  3. Force, Tension Measurement
  4. Industrial Automation
  5. Pallet Scale
Get Best QuoteRequest A Callback
Button Load Cell
  • Button Load Cell
  • Button Load Cell

Button Load Cell

Get Latest Price

Product Brochure

Product Details:
BrandADI
Model90610-B
Capacity50 Kg- 450 Ton
MaterialAlloy Steel
Ingress ProtectionIP65
ApplicationCompression Testing
FeaturesHigh Accuracy & Precision
Load Cell CertificationsOIML
Output Sensitivity(FS)2.0 +/- 0.2 mV/V
Creep Error (30 minutes)<= +/- 0.04
Accuracy ClassOIML R60 C3
Temperature Effect on Zero<= +/- 0.005
Temperature Effect on Output<= +/- 0.005
Zero balance+/- 1% FS
Maximum Safe Overload150% FS
Ultimate Safe Overload200% FS
Recommended Excitation Voltage10 to 12V DC
Maximum Excitation Voltage15V DC
Input Resistance770 +/- 20 Ohm
Output Resistance700 +/- 7 Ohm
Insulation resistance at 50V DC>= 1000 M Ohm
Compensated Temperature Range-10 to +40 Deg C
Operating Temperatue Range-35 to +65 Deg C
Load Cell Intervals (nLC)/Divisions3000
Cable Length5 Meter

We supply supreme quality Button Load Cell with the most superior standards and performance available.

Specifications:

  1. Silo, Tank, Vessel Weighing
  2. Low Profile, extremely compact loading assembly
  3. Allows Vessel expansion & contraction
  4. Integral Jacking Facility
  5. 1000 division accuracy
  6. Environmental Protection IP68/ IP69K
  7. Allowance for Angular Mis-alignment
Get Best QuoteRequest A Callback
S-Type Load Cell
  • S-Type Load Cell
  • S-Type Load Cell

S-Type Load Cell

Get Latest Price

Product Brochure

Product Details:
BrandThames
ModelT61
Capacity50 Kg- 1 Ton
MaterialStainless Steel
Ingress ProtectionIP67
ApplicationTensile Testing Machine
FeaturesCorrosion Resistant
Load Cell CertificationsOIML, NTEP
Output Sensitivity(FS)3.0 +/- 0.08 mV/V
Combined Error<= +/- 0.035
Creep Error (30 minutes)<= +/- 0.03
Accuracy ClassOIML R60 C3
Temperature Effect on Zero<= +/- 0.0025
Temperature Effect on Output<= +/- 0.005
Zero balance+/- 1% FS
Maximum Safe Overload150% FS
Ultimate Safe Overload300% FS
Recommended Excitation Voltage5 to 15V DC
Maximum Excitation Voltage15V DC
Input Resistance380 +/- 30 Ohm
Output Resistance350 +/- 1.5 Ohm
Insulation resistance at 50V DC>= 5000 M Ohm
Compensated Temperature Range-10 to +40 Deg C
Operating Temperatue Range-30 to +70 Deg C
Load Cell Intervals (nLC)/Divisions3000
Cable Length5 Meter

We provide finest quality S-Type Load Cell with the best in class standards and performance available

Features:

  • Designed for single or multiple load applications
  • Integral Loading Bracket
  • Truck Scale Conversions
  • Tension & Compression measurements
  • Level & Inventory Monitoring
  • Tank, Bin & Hopper Weighing
Get Best QuoteRequest A Callback

EXPLORE MORE CATEGORIES

Looking For "Load Cell"?
Thank youYour Enquiry has been sent successfully.
© Expert Weighing Solution. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.